As you know, the busbar differential protection function (87BB) is the main protection function for protecting busbars, and It relies on Kirchhoff’s current law. This law states that the vectorial sum of all currents flowing into a closed area must be zero.
Topics of busbar protection about how to configure and set the busbar protection parameters are recorded.
The various types of busbar arrangements are used in the power system. The selection of bus bar is dependent on the different factors for instance reliability, flexibility, cost, etc …
Electrical Power Lines and Pylons with Sunrise, Sunset. Vector EPS 10
DIgSILENT Power Factory software is one of the most powerful software in network analysis that will use in all the areas of generation, transmission, and distribution. DIgSILENT stands for DIgital SImuLation and Electrical NeTwork calculation program.
The purpose of this course:
Acquaint engineers with the process of analyzing power systems to carry out research, industrial and other projects. Using this software, almost any power network can be modeled and calculations such as load flow, short circuit, transient analysis, optimal capacitor placement, cable size optimization, etc. can be provided in the form of various functions. In addition, other features such as programming in DPL language and defining DSL models provide the flexibility for the user to perform the desired analysis on the power system and the equipment that is not available in the software library.
Main Training Materials:
Part A (2 hrs, 50 min)
P 01: Course Contents and details
P 02: Introduction of DIgSILENT
P 03: Comparision of common power system study software
P 04: Brief overview of DIgSILENT environment
P 05: DIgSILENT menu
P 06: DIgSILENT menu
P 07: Study tools in DIgSILENT
P 08: Creating a simple 3-bus system in DIgSILENT
P 09: Line/cable modeling and parameters
P 10: Generator modeling and parameters
P 11: Transformer modeling and parameters
P 12: Loads and busbar modeling and parameters
P 13-15: DIgSILENT Graphics, tools, and applications
P 16: Elements in DIgSILENT
P 17: Different scenarios, case studies, Variations
P 18: Different scenarios, case studies, Variations
P 19: Equipment modeling; External Grid
P 20: Load
P 21: Breaker/switch
P 22: Synchronous generator
P 23: Transformer
P 24: Line
P 25: Cable and Shunt/filter C or capacitor bank
P 26: Power flow study; Study setting
P 27: Power flow study; Different output and reporting
P 28: N-1 study; Study setting
P 29: N-1 study; Different output and reporting
P 30: Short-circuit study; Study setting
P 31: Short-circuit study; Different output and reporting
P 32: Transient study; Defining different events; Study setting
P 33: Transient study; Study setting; Different output and reporting